VACS:Projects:Software:LPS:Commands
From VACS
Revision as of 21:57, 3 November 2006 by Stephane.Carrez (Talk | contribs)
Power Supply Commands
When a power supply is selected, specific commands are available:
V[-]nnnnn |
|
Set the voltage in millivolts of the current power supply. Return the voltage that is set. Example:
Request: V10003 Reply: V10000 |
|
Innnn | |
Set the limiting current in milliamperes for the current power supply. Return the limiting current that is set.
Request: I2023 Reply: I2030 | |
CV[-]nnnnn | |
Set the calibration of the output voltage. This is the value that is measured by a multi-meter. It returns the voltage that was asked by the last 'V' command and the new calibration voltage. After this, the voltage is calibrated.
Request: CV9995 Reply: V10000 CV9995 | |
CInnnn | |
Set the calibration of the output current. This is the value that
is measured with a multi-meter. The output current measured internally is adjusted to match the calibrated value. Request: CI1023 Reply: i1000 CI1023 | |
TV[-]nnnnn | |
Set the thresold to choose between the +9 and +18 power supply
to drive the output power supply transistor. If the output power supply is bigger that the thresold, the power supply transistor is driven by the +18V. Otherwise it is driven by the +9V. Request: TV9000 Reply: TV9000 | |
TInnnn | |
Set the thresold to activate the second current mosfet driver.